  • Project number: GLD-A002
    Combination string: ICR18650-4 1 and
    Nominal voltage: 14.8V
    Voltage range: 12-16.8V
    Nominal capacity: 2.2AH
    Products:350m ohm internal resistance of battery
    Battery size: MAX 37*37*67mm
    Maximum discharge current: > 10A ( according to customer requirements to current amplification or reduction)
    Discharge current moment: > 6A ( according to customer requirements to current amplification or reduction )
    Maximum charging current: > 0.2-0.5C ( according to customer requirements to current amplification or reduction )
    Working temperature: 0~45 ℃: charging
    Discharge: -20~60 ℃
    Charge and discharge times: > 500 times
    Optional: Sanyo Electric core brand
    Lead and plug type: customized according to customer requirements
    Protection parameters: according to customers customized products